1,979 research outputs found

    Microscopy of Quantum Many-Body Systems out of Equilibrium

    No full text

    Response of Bose gases in time-dependent optical superlattices

    Full text link
    The dynamic response of ultracold Bose gases in one-dimensional optical lattices and superlattices is investigated based on exact numerical time evolutions in the framework of the Bose-Hubbard model. The system is excited by a temporal amplitude modulation of the lattice potential, as it was done in recent experiments. For regular lattice potentials, the dynamic signatures of the superfluid to Mott-insulator transition are studied and the position and the fine-structure of the resonances is explained by a linear response analysis. Using direct simulations and the perturbative analysis it is shown that in the presence of a two-colour superlattice the excitation spectrum changes significantly when going from the homogeneous Mott-insulator the quasi Bose-glass phase. A characteristic and experimentally accessible signature for the quasi Bose-glass is the appearance of low-lying resonances and a suppression of the dominant resonance of the Mott-insulator phase.Comment: 20 pages, 9 figures; added references and corrected typo

    New design of electrostatic mirror actuators for application in high-precision interferometry

    Get PDF
    We describe a new geometry for electrostatic actuators to be used in sensitive laser interferometers, suited for prototype and table top experiments related to gravitational wave detection with mirrors of 100 g or less. The arrangement consists of two plates at the sides of the mirror (test mass), and therefore does not reduce its clear aperture as a conventional electrostatic drive (ESD) would do. Using the sample case of the AEI-10 m prototype interferometer, we investigate the actuation range and the influence of the relative misalignment of the ESD plates with respect to the test mass. We find that in the case of the AEI-10 m prototype interferometer, this new kind of ESD could provide a range of 0.28 ÎĽm when operated at a voltage of 1 kV. In addition, the geometry presented is shown to provide a reduction factor of about 100 in the magnitude of the actuator motion coupling to the test mass displacement. We show that therefore in the specific case of the AEI-10 m interferometer, it is possible to mount the ESD actuators directly on the optical table without spoiling the seismic isolation performance of the triple stage suspension of the main test masses

    Review of the Laguerre-Gauss mode technology research program at Birmingham

    Get PDF
    Gravitational wave detectors from the advanced generation onwards are expected to be limited in sensitivity by thermal noise of the optics, making the reduction of this noise a key factor in the success of such detectors. A proposed method for reducing the impact of this noise is to use higher-order Laguerre-Gauss (LG) modes for the readout beam, as opposed to the currently used fundamental mode. We present here a synopsis of the research program undertaken by the University of Birmingham into the suitability of LG mode technology for future gravitational wave detectors. This will cover our previous and current work on this topic, from initial simulations and table-top LG mode experiments up to implementation in a prototype scale suspended cavity and high-power laser bench

    Photon pressure induced test mass deformation in gravitational-wave detectors

    Get PDF
    A widely used assumption within the gravitational-wave community has so far been that a test mass acts like a rigid body for frequencies in the detection band, i.e. for frequencies far below the first internal resonance. In this article we demonstrate that localized forces, applied for example by a photon pressure actuator, can result in a non-negligible elastic deformation of the test masses. For a photon pressure actuator setup used in the gravitational wave detector GEO600 we measured that this effect modifies the standard response function by 10% at 1 kHz and about 100% at 2.5 kHz

    DC-readout of a signal-recycled gravitational wave detector

    Full text link
    All first-generation large-scale gravitational wave detectors are operated at the dark fringe and use a heterodyne readout employing radio frequency (RF) modulation-demodulation techniques. However, the experience in the currently running interferometers reveals several problems connected with a heterodyne readout, of which phase noise of the RF modulation is the most serious one. A homodyne detection scheme (DC-readout), using the highly stabilized and filtered carrier light as local oscillator for the readout, is considered to be a favourable alternative. Recently a DC-readout scheme was implemented on the GEO 600 detector. We describe the results of first measurements and give a comparison of the performance achieved with homodyne and heterodyne readout. The implications of the combined use of DC-readout and signal-recycling are considered.Comment: 11 page

    Triple Michelson Interferometer for a Third-Generation Gravitational Wave Detector

    Full text link
    The upcoming European design study `Einstein gravitational-wave Telescope' represents the first step towards a substantial, international effort for the design of a third-generation interferometric gravitational wave detector. It is generally believed that third-generation instruments might not be installed into existing infrastructures but will provoke a new search for optimal detector sites. Consequently, the detector design could be subject to fewer constraints than the on-going design of the second generation instruments. In particular, it will be prudent to investigate alternatives to the traditional L-shaped Michelson interferometer. In this article, we review an old proposal to use three Michelson interferometers in a triangular configuration. We use this example of a triple Michelson interferometer to clarify the terminology and will put this idea into the context of more recent research on interferometer technologies. Furthermore the benefits of a triangular detector will be used to motivate this design as a good starting point for a more detailed research effort towards a third-generation gravitational wave detector.Comment: Minor corrections to the main text and two additional appendices. 14 pages, 6 figure

    Quantum noise of non-ideal Sagnac speed meter interferometer with asymmetries

    Get PDF
    The speed meter concept has been identified as a technique that can potentially provide laser-interferometric measurements at a sensitivity level which surpasses the Standard Quantum Limit (SQL) over a broad frequency range. As with other sub-SQL measurement techniques, losses play a central role in speed meter interferometers and they ultimately determine the quantum noise limited sensitivity that can be achieved. So far in the literature, the quantum noise limited sensitivity has only been derived for lossless or lossy cases using certain approximations (for instance that the arm cavity round trip loss is small compared to the arm cavity mirror transmission). In this article we present a generalised, analytical treatment of losses in speed meters that allows accurate calculation of the quantum noise limited sensitivity of Sagnac speed meters with arm cavities. In addition, our analysis allows us to take into account potential imperfections in the interferometer such as an asymmetric beam splitter or differences of the reflectivities of the two arm cavity input mirrors. Finally,we use the examples of the proof-of-concept Sagnac speed meter currently under construction in Glasgow and a potential implementation of a Sagnac speed meter in the Einstein Telescope (ET) to illustrate how our findings affect Sagnac speed meters with meter- and kilometre-long baselines.Comment: 22 pages, 8 figures, 1 table, (minor corrections and changes made to text and figures in version 2

    The upgrade of GEO600

    Get PDF
    The German / British gravitational wave detector GEO 600 is in the process of being upgraded. The upgrading process of GEO 600, called GEO-HF, will concentrate on the improvement of the sensitivity for high frequency signals and the demonstration of advanced technologies. In the years 2009 to 2011 the detector will undergo a series of upgrade steps, which are described in this paper.Comment: 9 pages, Amaldi 8 conference contributio
    • …
    corecore